Goyen Pulse Jet Valves

  • Goyen CA15T Screw Pulse Jet Valves

    Goyen CA15T Screw Pulse Jet Valves

    1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
    2. Ensure tank and pipes are free from dirt, rust or other particulate.
    3. Ensure supply air is clean and dry.
    4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
    5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
    6. Apply moderate pressure to system and check for installation leaks.